Guide
What C2 Means on an EICR, and What Happens Next
By Alan Cuzen, electrician with 30 years in the trade, based in Glasgow.
Rules checked
If your Electrical Installation Condition Report (EICR) has come back with a C2 on it, the electrician has found something potentially dangerous. Here's what the codes mean, what a C2 usually covers, and what happens next, whether you own your home or rent it out.
The short answer
- C2 means "potentially dangerous". It isn't an immediate danger on the day of the inspection, but it would become one if a fault or another foreseeable event happened. Urgent remedial action is required.
- Any C2 makes the whole report Unsatisfactory, and so does any C1. On reports written before the 2026 update to the wiring regulations, an FI did too.
- A qualified electrician needs to put it right, and should give you a certificate for the work.
- Landlords have legal deadlines and paperwork, which are different in England, Wales and Scotland.
What an EICR is
An EICR is the report an electrician writes after inspecting and testing a property's fixed electrical installation: the wiring, the consumer unit (fuse box), sockets, switches and light fittings. It's written on a model form from BS 7671, the UK wiring regulations.
The report lists observations, gives each one a code, gives the installation an overall result, and recommends when the next inspection should be. It isn't a fault-finding exercise. The electrician reports on the condition of the installation within the extent and limitations agreed beforehand, which are written on the report.
The four codes
| Code | What it means | What it asks for |
|---|---|---|
| C1 | Danger present. Risk of injury. | Immediate remedial action. The electrician should tell you straight away, and may deal with the danger before leaving, for example by isolating the faulty part. |
| C2 | Potentially dangerous. | Urgent remedial action. |
| C3 | Improvement recommended. | Not needed for a Satisfactory result, but putting it right would improve the safety of the installation. |
| FI | Further investigation. | Something the inspection couldn't fully check. It should be investigated as soon as possible, because it may turn out to be dangerous. |
Each observation gets one code: the most serious one that applies.
What a C2 can look like
Electrical Safety First's industry guidance on coding gives examples of things normally coded C2. In plain words, they include:
- no earth at a socket, or no reliable earth for the installation
- missing main bonding to incoming gas or water pipes
- no RCD protection for sockets likely to power equipment used outdoors
- an RCD that doesn't trip when it's tested
- live and neutral the wrong way round (incorrect polarity)
- loose or poorly made connections, or connections left open, for example at a light fitting
- cable sheath stopping short of a socket or switch, so the wires inside can be touched
- insulation that has broken down
- signs of overheating, such as scorch marks
- ordinary sockets too close to a bath or shower
- old rewireable fuses fitted with fuse wire that's too heavy.
The electrician decides each code on the day, based on what they find. If you're unsure why something has been coded C2, ask them to explain it. Photographs of each observation help.
Satisfactory or Unsatisfactory
At the end of the report, the electrician gives the installation an overall result: Satisfactory or Unsatisfactory. If any observation is coded C1 or C2, the result must be Unsatisfactory. If the only codes are C3, it can be Satisfactory.
FI changed in 2026. Until the 2026 update to the wiring regulations (BS 7671 Amendment 4), an FI also made the whole report Unsatisfactory, so older reports will show that. Under the current wording, FI means further investigation is advised, and on its own it doesn't make the result Unsatisfactory. Either way, an FI still needs investigating, and landlords in England must have it done within the same 28 days as a C1 or C2.
A Satisfactory result only holds until the date recommended for the next inspection.
If you own your home
There's no law requiring homeowners to have their electrics inspected, though houses in multiple occupation have their own rules. Electrical Safety First recommends an inspection at least every 10 years for a home you live in.
If your report has a C2:
- Get it put right by a qualified electrician as a matter of urgency. That can be the electrician who did the inspection or another qualified electrician.
- Ask for a certificate for the work. That's usually a Minor Electrical Installation Works Certificate, or an Electrical Installation Certificate for bigger jobs such as a new consumer unit. Keep it with your EICR.
- Check whether the work is notifiable. Replacing a consumer unit is notifiable in England and Wales: see Do I Need Part P to Add Extra Sockets? for how notification works in each nation.
You don't need an EICR to sell a house, but a buyer may ask for one.
If you're a landlord in England
The Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020 cover private landlords and, since 2025, social landlords too. You must:
- have the installation inspected and tested by a qualified person before a tenancy starts, then at least every five years, or sooner if the report says so
- give a copy of the report to existing tenants within 28 days of the inspection, to a new tenant before they move in, to a prospective tenant within 28 days of a written request, and to the council within 7 days of a written request
- keep a copy, and give it to the person who does the next inspection.
If the report needs remedial or further investigative work (C1, C2 or FI), a qualified person must do it within 28 days of the inspection, or sooner if the report says so. You then need written confirmation from them that the work is done, such as a satisfactory EICR, an Electrical Installation Certificate or a Minor Electrical Installation Works Certificate. Give that confirmation and the original report to your tenants and the council within 28 days of the work being finished.
C3s don't have to be put right under the regulations, though the government's guidance says acting on them would improve safety. If the work genuinely can't be finished in 28 days, for example because the energy supplier has to fit an isolator first, keep clear records: the regulations allow for landlords who have taken all reasonable steps. Datestone, another of Alan Cuzen's sites, can keep that record: dated photos, receipts and notes in one evidence pack.
If a tenant reports an electrical problem between inspections, Repair request sorter turns their message into a clear job description and an urgency level.
If you're a landlord in Wales
Under the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022:
- there must be a valid electrical condition report during each period of occupation. It must be carried out by a qualified person, and it's valid for five years, or less if the report says so
- the contract-holder must get a copy within 14 days of moving in, and within 14 days of any later inspection
- after any investigatory or remedial work, the contract-holder must get written confirmation from the qualified person within 14 days of you receiving it.
The Welsh regulations don't set a fixed number of days for remedial work the way England's do. C1 and C2 items still need acting on urgently, and the home must remain fit for human habitation.
If a tenant reports an electrical problem between inspections, Repair request sorter turns their message into a clear job description and an urgency level.
If you're a landlord in Scotland
The Repairing Standard statutory guidance, which applies from 1 March 2024, sets out what's expected:
- When: an EICR before the property is first let, then at least every five years. You also need in-service inspection and testing (often called PAT testing) of electrical equipment you provide.
- Who: a skilled person who is competent in the work. Registration with SELECT, NICEIC or NAPIT is accepted as evidence of competence, or the electrician can confirm the points on the guidance's checklist.
- C1 and C2: these must be put right to meet the Repairing Standard. C1 immediately, C2 urgently.
- FI: investigate as soon as practically possible.
- C3: not necessarily required, but the guidance asks landlords to consider them.
- RCD protection: there must be at least one 30 mA RCD in the main consumer unit, normally covering at least the socket circuits. Without one, the property doesn't meet the Repairing Standard. That holds even if your report codes missing RCD protection as C3, so don't rely on the code alone for this one.
- Paperwork: record remedial work on a Minor Electrical Installation Works Certificate, or an Electrical Installation Certificate if the consumer unit is replaced. Keep the EICR for six years, give a copy to a new tenant before the tenancy starts, and give your tenant a copy after any inspection during the tenancy. For a dated record of the repairs themselves, there's Datestone, another of Alan Cuzen's sites.
Tenants who think a property doesn't meet the Repairing Standard can apply to the First-tier Tribunal for Scotland (Housing and Property Chamber).
If a tenant reports an electrical problem between inspections, Repair request sorter turns their message into a clear job description and an urgency level.
Northern Ireland
Northern Ireland has its own rules, including for landlords, so check the Department for Communities guidance or ask your local council.
Getting the work done
- Use a qualified electrician. Remedial work on a C2 is a job for a qualified electrician, not a DIY fix.
- Get it in writing. Ask for a quote that refers to each observation on the report, so it's clear what's being put right.
- Get a certificate. Every piece of remedial work should come with a certificate. Keep it with the EICR.
- Don't wait on a second opinion. If you want another electrician to look at a C2, arrange it quickly. The code means urgent action is needed either way.
Sources
- Electrical Safety First: Best Practice Guide 4, Electrical installation condition reporting (Issue 7.4)
- The Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3
- Electrical safety standards in the private and social rented sectors: guidance (GOV.UK, 2025)
- The Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, regulation 6
- Repairing Standard: statutory guidance for private landlords (2024), Annex D3
- Department for Communities: Electrical Safety Standards for Private Tenancies (Northern Ireland)
- Electrical Safety First: periodic inspection and testing
This guide explains the rules in general terms and isn't a substitute for advice on your own property. Drafted with AI assistance and checked by Alan Cuzen.