Guide
Do I Need Part P to Add Extra Sockets?
By Alan Cuzen, electrician with 30 years in the trade, based in Glasgow.
Rules checked
Adding a double socket or two is one of the most common jobs in any home. Whether building control needs to know about it depends on where you live and where the socket is going. Here's how it works in each part of the UK.
The short answer
- England: adding sockets to an existing circuit usually isn't notifiable. It is if the work is in the space around a bath or shower, needs a new circuit, or means replacing the consumer unit (fuse box).
- Wales: the rules are wider. Adding sockets is notifiable in a kitchen, in a room with a bath or shower, or outdoors, and whenever it needs a new circuit or a new consumer unit.
- Scotland: Part P doesn't apply. Electrical work in a house usually doesn't need a building warrant, but it must still meet the Scottish building standards.
- Northern Ireland: the rules are different, so check with your local council's building control.
- Everywhere: the work should be done to BS 7671, the UK wiring regulations, then inspected, tested and certified.
What Part P is, and what it isn't
Part P is the part of the Building Regulations for England and Wales that covers electrical safety in homes. It isn't a qualification, and it isn't a type of electrician. When an electrician is described as "Part P registered", it means they belong to a competent person scheme that lets them certify their own notifiable work.
Part P applies to all electrical work in a home, notifiable or not. "Notifiable" only decides whether building control has to be told about the job.
England
In England, three kinds of electrical work are notifiable:
- installing a new circuit
- replacing a consumer unit
- any addition or alteration to existing circuits in a special location.
A special location is the space around a bath or shower (up to 2.25 metres high, and 0.6 metres out from the edge of the bath or shower tray), or a room containing a swimming pool or sauna heater.
So adding sockets to an existing circuit in a living room, bedroom, hall or kitchen isn't notifiable in England, as long as the job doesn't need a new circuit or a new consumer unit. Kitchens used to be notifiable, but that changed in April 2013. A new socket in a bathroom is unlikely anyway: ordinary sockets can't go within 2.5 metres of the edge of zone 1, the space directly above a bath or shower tray.
The job does become notifiable if it needs a new circuit, for example to a garden room or an outbuilding, or if the consumer unit has to be replaced to protect the new sockets properly.
Notifiable work is certified in one of three ways: by an electrician registered with a competent person scheme, by a registered third-party certifier, or by building control, who must be told before the work starts. If you use a scheme electrician, you should receive a Building Regulations compliance certificate within 30 days of the work being finished.
Wales
Wales still uses an older version of Approved Document P, so more work is notifiable than in England. Adding sockets to an existing circuit is notifiable if the work is:
- in a kitchen (a room, or part of a room, with a sink and food preparation facilities)
- in a room with a bath or shower
- outdoors, including a socket on an outside wall
- or if it needs a new circuit or a replacement consumer unit.
Elsewhere in the house, such as a bedroom or living room, adding sockets to an existing circuit isn't notifiable, as long as the existing circuit's protection is suitable for the extra sockets.
Scotland
Part P doesn't apply in Scotland. Electrical work comes under the Building (Scotland) Regulations 2004 and the building standards set out in the Scottish technical handbooks.
Building warrants. The regulations list work that doesn't need a building warrant, and "any work to or in a house" is on that list, with some exceptions. The government's handbook names electrical work as an example. So adding sockets in a house usually doesn't need a warrant.
The exceptions matter, though. One is work that adversely affects a separating wall, and the handbook's own example is installing recessed sockets in one. That's worth knowing in a tenement flat, where walls are often shared with the neighbours. If your electrics are part of a bigger job that needs a warrant, such as an extension or a loft conversion, they're covered by that warrant.
No warrant doesn't mean no rules. Work that doesn't need a warrant must still meet the building standards, and it should be done, inspected, tested and certified to BS 7671.
Certificate of Construction. When electrical work is part of a job that does need a building warrant, an Approved Certifier of Construction can certify it. These certifiers belong to schemes approved by Scottish Ministers, and SELECT is one of the scheme providers. If a Certificate of Construction for the electrics goes in with your completion certificate, the council doesn't need to inspect the electrics. For a few sockets that don't need a warrant, you'll get the electrician's BS 7671 certificate instead, normally a Minor Electrical Installation Works Certificate.
If you rent out a property in Scotland
Under the Repairing Standard, private landlords must have an Electrical Installation Condition Report (EICR) carried out at least every five years, by a suitably competent electrician. There must also be RCD protection in the main consumer unit. If you add sockets to a rented property, keep the certificate for the work with your records. It doesn't replace the five-yearly EICR, which stays on its own cycle.
Northern Ireland
Northern Ireland has its own Building Regulations, so the rules differ: check with your local council's building control before you start.
Whatever the rules, you should get a certificate
Notifiable or not, new electrical work should be inspected, tested and certified to BS 7671. For extra sockets on an existing circuit, that's normally a Minor Electrical Installation Works Certificate. A new circuit or a new consumer unit gets an Electrical Installation Certificate. Keep them with your house papers: you may be asked for them when you sell, and landlords need them for their records.
Where the work is notifiable in England or Wales, you should also get a Building Regulations compliance certificate, or a completion certificate from building control. That's a separate document from the electrician's certificate.
When a simple extra socket becomes a bigger job
Before adding to a circuit, an electrician has to check that the existing installation can take it. The wiring regulations only allow an addition if the existing circuit and equipment are up to the extra load and in good enough condition, and the earthing and bonding are adequate. These are the things that can turn a small job into a bigger one:
- No RCD protection. New sockets need RCD protection, and so do cables buried less than 50 mm deep in walls, unless they're otherwise protected. If your fuse box doesn't have it, it may need adding, sometimes by replacing the consumer unit, and replacing a consumer unit is notifiable in England and Wales.
- A circuit that's already doing a lot. If the circuit is already heavily loaded or extended too far, a new circuit may be the right answer.
- Old or damaged wiring. Problems with the existing circuit need putting right before anything is added to it.
- Earthing problems. If the earthing or bonding isn't adequate, it has to be put right first.
None of this can be judged by eye. Only inspection and testing with the right instruments shows whether the circuit and the new sockets are fit for use.
Can I do it myself?
The rules apply to everyone, homeowners included. In England and Wales, notifiable work done by anyone who isn't a registered electrician must be reported to building control before the work starts. Our advice is to use a qualified electrician. New electrical work has to be inspected and tested with specialist instruments before anyone can say it's fit for use, and you'll get a certificate that records it.
Before you book the job
- Which nation is the property in?
- Is the new socket going in a kitchen, a bathroom or outside? (This matters most in Wales. In England, only the space around a bath or shower counts.)
- Will the job need a new circuit or a new consumer unit?
- In Scotland, is it going into a wall shared with a neighbour, or is it part of a bigger job that needs a warrant?
- Will you get a BS 7671 certificate and, where the work is notifiable, a Building Regulations certificate?
If you're unsure whether your job is notifiable, ask your electrician, or your local building control (in Scotland, your council's building standards service), before the work starts.
If the new sockets are for smart home kit, Nuztech, Alan Cuzen's smart home blog, has guides and reviews written for UK homes.
Sources
- Approved Document P: electrical safety, dwellings, 2013 edition (England)
- Approved Document P: electrical safety (dwellings), 2006 edition incorporating 2010 amendments (Wales)
- The Building (Scotland) Regulations 2004, schedule 3
- Building standards technical handbook 2022: domestic, section 0.5
- Repairing Standard: statutory guidance for private landlords (2024), Annex D3
- BS 7671, Requirements for Electrical Installations (IET Wiring Regulations)
This guide explains the rules in general terms and isn't a substitute for advice on your own job. Drafted with AI assistance and checked by Alan Cuzen.